New buildings and extensions must, as a rule, have a climate calculation under BR18, the Danish Building Regulations 2018 (section 297, § 297). There are exemptions, for example unheated buildings under 50 m² floor area. Each material must have a figure for its climate impact. The figure comes either from the state's generic data (in Danish) in Annex 2, Table 7 (bilag 2, tabel 7), or from an environmental product declaration, an EPD. Here is what an EPD contains, when it can be used and where to find it.
What does an EPD contain?
An EPD is based on a life cycle assessment (LCA) of the product. It states several environmental indicators, for example acidification and energy use. BR18 uses one of them: global warming (GWP, in Danish), stated in kg CO2e.
Three things mark an EPD:
- It follows EN 15804. The standard was revised in 2019. The new edition is called +A2, the old one +A1. In an +A1 EPD the climate figure is under GWP, in an +A2 EPD under GWP-total. BR18 accepts both, as long as the EPD is valid.
- It is verified by an independent third party before it is published.
- It is published by a programme operator. The programme operator sets the rules for how the EPD is made and verified. The Danish programme operator is EPD Danmark.
All figures are stated per declared unit, for example 1 m², 1 m³ or 1 tonne. If the invoice says pieces or metres, the quantity must be converted before the figure can be used. The unit can also be based on a property of the product. In Table 7, mineral wool is stated per m² with a thermal resistance (R) of 1 m²K/W. To use the figure, you need both the thickness and the λ value.
EPD and LCA: what is the difference?
An LCA, life cycle assessment, is the method: a calculation of the environmental impact through the whole life cycle. An EPD is the result of an LCA for one construction product, set out under EN 15804, verified and published. A BR18 climate calculation is an LCA of the whole building, and it uses EPDs and Table 7 as data for each material. In short: an EPD is based on an LCA of one product, and the building's LCA is based on many EPDs.
| EPD | LCA | |
|---|---|---|
| What is it? | A document with environmental data for one construction product | A calculation of the environmental impact through the life cycle |
| What does it cover? | A product or a product type | A product, a building element or a whole building |
| Who makes it? | The manufacturer, often with a consultant | For the building: the consultant or the client. For a product: the manufacturer |
| Rules | EN 15804 | For the building: BR18 section 297 and the guidance. For a product: EN 15804 |
| Check | Verified by an independent third party and published by a programme operator | For the building: documented to the municipality at completion |
| Unit | Per declared unit, for example 1 m² | For the building under BR18: kg CO2e per m² per year |
How the building's calculation is made from the invoices is in the guide to as-built LCA.
The life cycle modules: A1–A3, A4–A5, B, C and D
An EPD and a BR18 climate calculation divide the life cycle into the same modules:
| Module | What it covers | Limit in BR18 |
|---|---|---|
| A1–A3 | Raw materials, transport to the factory and manufacture | The building's |
| A4 | Transport to and from the site | The construction process's |
| A5 | Construction and installation: the site's energy and waste | The construction process's |
| B4 | Replacement of building parts | The building's |
| B6 | Energy use for operation | The building's |
| C3–C4 | Waste processing and disposal | The building's |
| D | Potential for reuse, recycling and other recovery | Stated separately, not in the limit |
From the EPD, A1–A3, C3, C4 and D are used. D must be in the calculation, but it does not count when the result is held against the limit. The transport (A4) can be taken from the EPD and scaled to the actual distance, calculated from fuel and electricity use, or stated with the state's fixed rates in Annex 2, Table 10. The construction process has its own limit, see the climate requirements for the construction process (in Danish).
If the EPD lacks both C3 and C4, a suitable waste module from Table 7 can be used. If the EPD has no value for D, the guidance recommends setting it to 0. The waste modules matter a great deal for timber. In Table 7, cross-laminated timber has −664 kg CO2e per m³ in A1–A3, because the timber's uptake of CO2 is recorded there. C3 has 744. Without C3, the account would count the uptake, but not the emission when the timber is finally burned.
Product EPD, industry EPD and generic data
BR18 names three kinds of EPD (section 297(8)):
- Product-specific EPD. Covers one product from one manufacturer. Some cover several variants and have scaling factors, so the figure can be adjusted to the specific variant.
- Project-specific EPD. Made for a material or product in that particular project.
- Industry EPD. An average for a product type, calculated jointly by several manufacturers.
If there is no EPD, generic data from Table 7 are used. No other generic data may be used.
BR18 does not rank the three kinds of EPD. The guidance calls a product-specific EPD more representative than generic data. The closer the figure is to the product actually built in, the better. What matters is that the data source can be traced for each line in the account.
What is the state's Table 7 made of?
Table 7 in Annex 2 is the state's generic data. The 2025 edition applies from 1 July 2025 and has 507 rows. The letter in the row's ID shows where the figure comes from:
| ID begins with | Source | Rows |
|---|---|---|
| G | Generic data from the German database ÖKOBAUDAT | 322 |
| D | Danish generic data | 132 |
| B | Industry EPDs from EPD Danmark | 38 |
| S | Standard values for technical installations | 15 |
The G, D and B rows have figures for A1–A3, C3, C4 and D per declared unit, where the module is relevant, and a mass factor that gives the weight. The mass factor makes it possible to convert the invoice's quantities. In DiFacto's review of the 2025 edition, 473 of the 507 rows could be converted to a figure per kg. The other 34 are the standard values, which apply per m² heated floor area per year, and rows where the thickness or the λ value is not clearly stated.
The table refers to the source behind each row, and the source can have an expiry date. According to the guidance, that date is not relevant for the requirement.
An example. The invoice line is made up; the Table 7 figures are from the 2025 edition. The invoice says 30 pieces of plasterboard, 900 × 2,400 mm. Table 7's row for standard plasterboard (#D1515) is stated per m²: 1.727 kg CO2e in A1–A3, and the board weighs 9.1 kg per m². 30 boards are 64.8 m². That gives 111.9 kg CO2e in A1–A3, and the boards weigh 590 kg. If the manufacturer has a valid EPD for that exact board, its figures can be used instead.
Where do you find an EPD?
Start with the invoice. The item text and the item number (in Danish) show which product it is and who made it. Find the manufacturer's own product name, for example on the wholesaler's product page. Then search for the manufacturer and the product name in the EPD databases.
- The manufacturer's own site. Look under the product's documentation, or ask the supplier.
- EPD Danmark. Set up in 2014. The database holds the EPDs published with EPD Danmark, as PDFs. It can be filtered by category, product or industry EPD, year of validity and +A1 or +A2. If you cannot find an EPD, it may have expired. EPD Danmark keeps a list of invalid EPDs.
- ECO Platform. An international association that works for common rules for EPDs, together with programme operators, manufacturers and others. Its ECO Portal searches across the participating programme operators and shows where each EPD is published. Searching is free. Downloading an EPD requires a free account, and access via API requires a licence.
- ÖKOBAUDAT. The German building ministry's database of environmental data for construction products, free and public. It holds both generic datasets and EPDs. Table 7's G rows come from here. The EPDs in it can be used instead of Table 7; the generic datasets cannot.
- Other programme operators, for example The International EPD System, have their own EPD libraries. An EPD does not have to be Danish to be used under BR18.
When can the EPD be used?
An EPD can replace Table 7 when four conditions are met:
- It is relevant. The product declared in the EPD must be the product used. An industry EPD is relevant when the product matches the EPD's product description.
- It is valid. An EPD applies for up to five years from issue, and the period of validity is stated in it. What matters is that it was valid when the product was used in the construction. It can therefore be used even if it expires before completion (færdigmelding). An EPD that is published later can also be used, if it is valid and covers that exact product. The invoice date shows when the product was bought, not when it was used. It is therefore a guide, not proof.
- It meets the requirements for an EPD. It is made under EN 15804, verified by an independent third party and published by a programme operator.
- The modules come from the same EPD. If the EPD lacks both C3 and C4, a suitable waste module from Table 7 may be used.
If two EPDs are based on different editions of EN 15804 or on different declared units, their figures cannot be compared directly. If you are in doubt whether an EPD can be used in a specific project, the municipality decides as the building authority.
Does BR18 require an EPD for construction materials?
No. BR18 requires a climate calculation for the building (section 297), not an EPD for each construction product. Each material must have a climate figure, and the starting point is the state's generic data in Annex 2, Table 7. Generic data from other sources may not be used. If no row represents the material, the figures for its components are used.
An EPD may be used instead of Table 7 (section 297(8)) when it meets the four conditions above: it covers the product used, it was valid when the product was used, it is made under EN 15804, verified by a third party and published by a programme operator, and the modules come from the same EPD. Generic data may therefore always be used when no EPD is used. If you are in doubt about a specific project, the municipality decides. The limit values the calculation must stay below are on BR18 and LCA (in Danish).
How do you get an EPD?
It is the manufacturer who has an EPD made for its product. A contractor or tradesperson does not get an EPD themselves, but finds the manufacturer's or asks the supplier for it. The process for the manufacturer:
- Choose a programme operator. The programme operator publishes the EPD and sets the rules for how it is made and verified. In Denmark it is EPD Danmark. An EPD from a foreign programme operator can also be used under BR18.
- Collect data from production. Raw materials, energy, transport and waste from the factory.
- Make the life cycle assessment. The LCA is made under EN 15804 and the programme operator's rules, often by a consultant. EPD Danmark has guidelines for the consultant's work.
- Have it verified. An independent third party reviews the calculation. EPD Danmark keeps a list of verifiers, and an EPD is not valid until it is verified under ISO 14025.
- Have it published. The programme operator registers and publishes the EPD. With EPD Danmark, the valid edition is always the one on its website. It applies for up to five years.
What the price depends on is in the questions below.
Why the tradesperson is asked
It is the client who must document the climate calculation on the building case at completion. But the calculation must show the materials actually used, and the party that bought them knows them. Item text, item number, quantity and date are on your invoices.
If you are asked for a list of materials and EPDs, you must be able to find the job's invoices. Collect them per job while the job is running. For each material line, note where the figure comes from: a product or industry EPD with its period of validity (for example valid until 25 September 2029), or a row in Table 7 with its ID. Write down the data source, not an assessment of the product. The terms are explained in the glossary (in Danish).
How DiFacto does it
DiFacto's climate calculation is a CO2 account under BR18 for each construction project. It is made from the invoices you upload or, with the AutoPilot add-on, send to your DiFacto email address. Each material line is matched to a data source in this order: first the product's own EPD, then an industry EPD and otherwise Table 7. The data source is shown on each line.
If you have an EPD as a PDF, you can upload it on the material line. The system reads it and uses the figures at the next recalculation, and the PDF is kept as documentation behind the figure. If the system cannot read it reliably, it rejects it instead of guessing. The BR18 report can be downloaded as a PDF, and the account as an Excel file for the consultant.
The climate calculation is an add-on to the subscription for companies in construction. The price is in the price calculator (in Danish). Read more about the climate calculation from invoices (in Danish). In English, the method step by step is in the guide to as-built LCA, with a whole house in the worked example.