An LCA under BR18, the Danish building regulations, divides the building's life into modules. The first five, A1 to A5, are about getting the building up: the materials, the transport and the work on the site. Here is what each module covers, which data the rules require, and where a supplier invoice can supply it. The limit values are in BR18 LCA requirements.
The five modules on one page
BR18 section 297(4) lists the modules. A1 to A3 are almost always reported together, because EPDs and the state's Table 7 do so.
| Module | Name in BR18 | What it covers | Data under BR18 |
|---|---|---|---|
| A1 | Raw materials | Extraction of the raw materials | EPD or Table 7 (A1–A3 together) |
| A2 | Transport | The raw materials are carried to the factory | EPD or Table 7 (A1–A3 together) |
| A3 | Manufacture | Production at the factory | EPD or Table 7 (A1–A3 together) |
| A4 | Transport to and from the site | Materials and equipment to the site, handling on the way | Measured consumption or the rates in Table 10 |
| A5 | Construction/installation | Energy on the site, construction waste and offcuts, removal of waste and soil | Measured consumption, Table 10 and Table 11 |
The two limits in section 298 share the modules between them. A1–A3 counts in the building's limit together with replacement (B4), operation (B6) and disposal (C3–C4). A4 and A5 have their own limit for the construction process. Module D is part of the calculation, but not of the limits. B, C and D are explained in the guide to EPDs.
The LCA stages A1–D in one table
The modules belong to four stages in the building's life and a fifth part outside it. BR18 does not count every module: the building's limit covers A1–A3, B4, B6 and C3–C4, and the construction process limit covers A4–A5 (section 298).
| Stage | Modules | What it covers | In BR18's limits? |
|---|---|---|---|
| Product stage | A1–A3 | Raw materials, transport to the factory and manufacture | Yes, the building's limit |
| Construction stage | A4–A5 | Transport to the site and construction with energy, waste and offcuts | Yes, the construction process limit |
| Use stage | B1–B7 | Use, maintenance, repair, replacement (B4), refurbishment, operational energy (B6) and water | Only B4 and B6 |
| End-of-life stage | C1–C4 | Demolition, transport, waste processing (C3) and disposal (C4) | Only C3 and C4 |
| Outside the life cycle | D | Reuse and recycling after disposal | No, reported separately |
A1–A3: the manufacture of the materials
A1–A3 is what a material has emitted before it leaves the factory. The rule is in section 297(7) and (8): use the generic data in Annex 2, Table 7, or an EPD that is relevant and valid and made to the standard EN 15804. What an EPD is, and when it can be used, is in the guide to EPDs.
The figures in Table 7 and in an EPD are given per kg, per m², per m³ or per piece. The quantity must therefore be converted to the data source's unit, and usually also to kilos.
What the invoice can supply: the item number and text, which lead to the product and the manufacturer, and so to an EPD if there is one. The quantity and the unit, which are the basis of the calculation. The supplier and the date, which show when and where the item was delivered.
What the invoice cannot supply: the CO2 figures themselves. They are in the EPD or Table 7. Often not the weight either, since an invoice in pieces, metres or m² does not say what the item weighs. And the invoice does not say whether the item was built in. Items bought by others are not on your invoices.
A4: transport to and from the site
A4 is the transport of materials from factory, warehouse or builders' merchant to the site, handling on the way and the transport of equipment. BR18 gives two routes in Annex 2, Table 10:
- Measured consumption. Litres of fuel, or kilometres driven times consumption per kilometre, multiplied by the emission factors in Tables 8.1 and 8.2.
- Rates per kg. A rate per kg of material that is part of the building, by material group. Ready-mixed concrete has 0.0024 kg CO2e per kg, and plasterboard 0.0166. If the rates are used, 0.02 kg CO2e per m² per year is added for surplus materials and packaging.
Terminal processes always count 0.02 kg CO2e per m² per year. Transport of equipment can use the same fixed rate instead of measured consumption. Equipment under 1 tonne, and materials that are not in Table 6, can be left out (section 297(9)).
What the invoice can supply: the kilos. Once a material line has been converted to kg for A1–A3, the same kg can be multiplied by the rate for the material group. If you deliver the materials yourself, the fuel invoice can give litres.
What the invoice cannot supply: kilometres and litres for the supplier's truck. A freight line shows that there was a delivery, but not how far or with what. That is why the rates per kg are often the route there is data for.
A5: construction and installation
A5 is the work on the site. It has three parts:
- Energy on the site: electricity, heating and fuel. There is no fixed rate. Consumption must be measured and multiplied by Tables 8.1 and 8.2. Machines under 1 tonne can be left out.
- Construction waste, including waste and offcuts: kg per fraction times the rate in Table 11, or the product EPD's A1–A3 and C3–C4. If the waste is collected mixed, the highest rate among the fractions is used.
- Removal of construction waste and soil: measured consumption, or a fixed 0.06 kg CO2e per m² per year for each.
What the invoice can supply: litres from the fuel card and fuel invoices, kWh from the electricity bill for the site supply and consumption from the district heating bill. Invoices from the waste receiver and weighbridge tickets give kg per fraction.
What the invoice cannot supply: the waste. The invoice shows what was bought, not what was built in. The waste is the difference, and you have to estimate or measure it yourselves. A fuel card invoice for a whole month does not say which site the diesel went to either. How each item is calculated is in the climate requirements for the construction process (in Danish).
Example: one line of plasterboard in A4 and A5
Invented figures. 3,000 kg of plasterboard is bought. 150 kg becomes offcuts, so 2,850 kg is built in.
- A4: 2,850 kg × 0.0166 = 47.3 kg CO2e. The rate applies to the material that is part of the building.
- A5: 150 kg of offcuts × 0.33 (ordinary gypsum in Table 11) = 49.5 kg CO2e.
The invoice gave the 3,000 kg, or the number of boards they were calculated from. The waste came from the site.
How DiFacto does it
DiFacto's climate calculation is an add-on for companies in construction. The system reads the material lines on the supplier invoices and matches each item to a data source: the product's EPD, an industry EPD or Table 7. The quantity is converted to kilos. If the weight is missing, you get a question.
The purchase is split into built in and waste, and the waste counts in A5. Transport in A4 is calculated with the rates per kg, and the fixed items are added from the floor area. Energy on the site only counts once you enter litres and kWh. Until then, the result says it is missing. The invoices come in by upload, or with the AutoPilot add-on via your own DiFacto email address. The steps from invoice line to kg CO2e are in as-built LCA from purchase invoices.